Example project

Cast stone heads and cills across a plot mix.

Semi-dry cast stone comes out of the mould while it is still green, so the mould has to let go of an arris it could easily damage. Six profiles that had to look like one family.

RouteCast moulds, semi-dry
ProfilesSix
SectorHousebuilder
Route
Cast moulds
Product
Cast stone heads and cills
Profiles
Six in one family
Standard
BS 1217 cast stone
Precast units with a deep riven stone face stacked on edge in a galvanised yard rack with timber spacers

The brief

A plot mix that needed one look and six sections.

A housebuilder was producing cast stone heads and cills for a development with several house types. The window openings were not all the same, so there were six sections in the package, and every one of them had to read as part of the same family once the units were up on an elevation.

Production was semi-dry, which is the normal route for cast stone under BS 1217 and is a different problem from wet cast: the mix is nearly dry, it is compacted rather than poured, and the unit comes out of the mould immediately.

The difficulty

The unit is struck while it is green.

This is the fact that decides everything about a semi-dry mould. The unit leaves the mould with no strength in it. An arris on a weathered cill is a thin edge of barely bound material at that moment, and if the mould drags on it at all, the edge is gone. The damage does not appear at the mould, it appears later as a chipped line on an elevation, and by then several hundred units have been made the same way.

The second difficulty was the family. Six sections drawn by different hands over the life of a house type range had inconsistent weatherings, different throat details and two different nose radii. Made exactly as drawn they would have produced an elevation where the cills did not belong to the heads.

Hardness pulls in two directions here. A soft face releases a green arris kindly and deforms under compaction. A hard face holds the section under compaction and is less forgiving on release.

How we did it

Rationalise the family, then make the mould let go.

01

One drawing review before any tooling

We put the six sections on top of each other and came back with a rationalised set: one nose radius, one throat, one weathering angle, with the widths and lengths left alone because those are what the openings need. The housebuilder's technical department signed it off, and the elevation now has six sizes of the same detail.

02

Draft and a hardness chosen for a green strike

Every vertical face in the mould got draft so the unit rises out rather than rubbing its way out, and the face hardness was set at the softer end of what would hold the section under compaction. That is the compromise the job needs, and it is set by which failure is more expensive, which here is a chipped arris.

03

A trial on the awkward section first

We trialled the deepest weathering rather than the simplest cill, because a trial that only proves the easy part of a family has proved nothing. The compaction and strike were watched on the customer's own press and their own mix before the other five were committed.

04

Then the same family, six times

The remaining moulds came off the signed-off geometry, so a replacement mould for one profile still matches the other five and a repeat order is a making job rather than a design job.

The numbers

Six moulds spread across the units they make.

Indicative and cited. Cast stone tooling is the case where the per unit figure is genuinely small.

The six moulds together present about 2.1 square metres of moulding face. At an indicative £350 per square metre that is £735 of tooling for the set. Take a working assumption of 250 uses from each mould, which is well inside the hundreds of pours normally quoted for a silicone face, and the set produces 1,500 units. £735 divided by 1,500 is about £0.49 of tooling in each head or cill.

Where a standard texture will do, catalogue panels are a different and lower conversation: Betonblock’s published panel prices run from £145 to £270 a panel. That was not this job, because a rationalised family of six sections is by definition bespoke, but it is the comparison a buyer should make before commissioning anything. All of the arithmetic below runs at the same indicative rate of £350 per square metre of liner, from published figures from PERI UK and RECKLI. It is a market figure carried here so the division can be checked, and the liner calculator will run it on your own rate instead.

The number that actually mattered on this job was not the 49 pence. It was that a dragged arris turns a good unit into a reject after all the material and all the handling have been paid for.

Every money figure on this page is indicative. It is taken either from the illustrative two year duty cycle used across all five TCI sites or from published third-party pricing, and it is shown so the arithmetic can be checked. None of it is a quotation, and all of it must be replaced with TCI figures before launch.

Where it got to

Where the job ended up.

  • Six drawn sections rationalised to one nose radius, one throat and one weathering
  • Draft on every vertical face and a face hardness chosen for a green strike
  • Trialled on the deepest weathering, on the customer's own press and mix
  • About 49 pence of tooling per unit on the indicative rate and a 250 use assumption

More jobs

Other work of this kind.

Every example project

Similar job?

Cast stone arrises chipping on strike?

Tell us the mix, the compaction method and where on the section it chips. That is usually enough to tell draft from hardness.